When to call each inspection, what the inspector actually looks at, and the failure that sends that call back most often — by trade. Written for the crew reading it from the truck, not for the plan room.
Oregon note: Oregon jurisdictions commonly allow a combined trade inspection request but still require separate permits per trade.
Two calls on most re-roofs; a same-week turnaround is typical.
When: After tear-off and underlayment, before any covering goes down
Most common fail: Shingles already loaded and partially laid over the dry-in, so the inspector cannot verify the deck or fastening.
Have on site: Approved permit card posted and visible from the street, with the approved plan set on site
When: Combined with dry-in in most jurisdictions; separate in high-wind areas
Most common fail: Installed fastener does not match the number listed on the application's product approval.
Have on site: Product approval / evaluation report printouts for the installed system
When: After the covering, ridge vent and all flashing are complete
Most common fail: Open penetrations or missing pipe boots on a roof otherwise complete.
Have on site: Approved permit card posted and visible from the street, with the approved plan set on site
One call on a straight changeout; two when ducts or gas lines are opened.
When: Only when ducts, refrigerant lines or gas piping are opened or concealed
Most common fail: Concealed duct closed in before the call, requiring re-opening the ceiling.
Have on site: Approved permit card posted and visible from the street, with the approved plan set on site
When: After the equipment is set, charged and running
Most common fail: Secondary condensate protection missing on an attic air handler, or the AHRI numbers on the permit not matching the tags on the equipment.
Have on site: Equipment invoice, AHRI certificate and load calculation when tonnage changed
Up to three calls; rough and top-out cannot be combined.
When: Before any trench is backfilled or slab is poured
Most common fail: Test gauge already bled off when the inspector arrives.
Have on site: Test gauge under pressure, trenches open
When: After walls are piped and vented, before drywall
Most common fail: Missing nail plates where pipe passes within 1-1/4" of a stud face.
Have on site: Approved permit card posted and visible from the street, with the approved plan set on site
When: After fixtures are set and the system is live
Most common fail: Water heater T&P line terminated in the pan or turned up instead of run to an approved point of discharge.
Have on site: Water heater data plate accessible
Two to three calls; the meter release is scheduled with the utility.
When: After boxes and cable are in, before insulation and drywall
Most common fail: Insulation already installed over the wiring, hiding staples and box fill.
Have on site: Approved permit card posted and visible from the street, with the approved plan set on site
When: On a service change, before the utility reconnects
Most common fail: Utility not scheduled in parallel, leaving the home off power overnight after a passed inspection.
Have on site: Signed load calculation and the utility work-order number
When: After devices, fixtures and the panel schedule are complete
Most common fail: Handwritten or missing panel directory after a panel change.
Have on site: Approved permit card posted and visible from the street, with the approved plan set on site
Typically one call, two when openings are altered.
When: After the unit is set and fastened, before stucco, siding or interior trim
Most common fail: Manufacturer labels removed before inspection, so the design pressure cannot be verified against the opening schedule.
Have on site: Manufacturer installation instructions and product approval for each unit
When: After trim, sealant and interior finish are complete
Most common fail: A replacement bedroom window that no longer meets minimum egress clear opening.
Have on site: Approved permit card posted and visible from the street, with the approved plan set on site
One or two calls depending on whether a WRB inspection is required.
When: After housewrap and flashing, before the cladding covers it
Most common fail: Reverse-lapped housewrap above openings, found only after cladding is removed.
Have on site: Approved permit card posted and visible from the street, with the approved plan set on site
When: After cladding, trim and sealant are complete
Most common fail: No EPA Lead-Safe RRP documentation available on a pre-1978 home when the inspector asks.
Have on site: RRP certification and containment record on pre-1978 homes
Often permit-exempt; where required, a single final call.
When: After gutters, downspouts and leaders are complete
Most common fail: Downspout discharging over the property line, triggering a drainage review.
Have on site: Approved permit card posted and visible from the street, with the approved plan set on site
Four or more calls; rough trades must pass before framing is covered.
When: After structural framing and before rough trades are concealed
Most common fail: A wall removed as non-bearing that the plans examiner reads as bearing, with no engineered header detail.
Have on site: Approved plans plus any engineer's letter for altered structure
When: Mechanical, plumbing and electrical rough, before insulation
Most common fail: One trade's separate permit never pulled, voiding the whole call.
Have on site: All trade permits posted together
When: After rough trades pass, before drywall
Most common fail: Compressed batts behind wiring and boxes, reading below the filed R-value.
Have on site: Energy compliance form filed with the permit
When: After all finishes and trade finals
Most common fail: Bath fan ducted into the attic instead of to the exterior.
Have on site: Approved permit card posted and visible from the street, with the approved plan set on site
Five or more calls from footing to certificate of occupancy.
When: Trench open, steel set, before concrete
Most common fail: Concrete trucks scheduled ahead of the call and the pour started early.
Have on site: Form survey and approved plans
When: After sheathing, roof dry-in and rough trades are in place
Most common fail: Missing hurricane or seismic connectors called out on the engineered sheet.
Have on site: Truss package and engineering on site
When: Mechanical, plumbing and electrical rough, before insulation
Most common fail: One sub's permit not pulled, so no trade rough can be signed.
Have on site: All trade permits and current sub license numbers
When: After rough trades pass, before drywall
Most common fail: Duct blower test not scheduled, holding the drywall crew.
Have on site: Energy compliance and duct test report
When: After all finishes and every trade final has passed
Most common fail: An open trade permit no one closed, blocking the certificate of occupancy.
Have on site: Approved permit card posted and visible from the street, with the approved plan set on site
Two calls, plus utility sign-offs collected before the first.
When: Before any structure is touched
Most common fail: Asbestos survey not attached, which stops demolition regardless of the permit.
Have on site: Utility disconnect letters and the asbestos survey
When: After the structure is removed and the site is backfilled
Most common fail: Foundation walls left in place below grade when full removal was permitted.
Have on site: Disposal tickets
Call-in windows, cutoffs and which calls can be combined are set locally by the office below.
Files with
Online portal: Development Hub PDX
Oregon CCB contractor licensing is required statewide.
Portland adds its own seismic and stormwater standards.
Most failed inspections trace back to the application: a product approval that doesn't match what was installed, a missing load calculation, a scope too vague for the examiner. RapidPermit Systems builds the Portland packet from your shop profile and the job scope, so the paperwork matches the work before the inspector ever shows up.
We'll email the Portland, OR inspection order and the documents each call expects on site.